Heatproof
Home / system #1136

Grant Aerona HP290

Compton and Shawford, Hampshire · Detached · 265 m² · 1900 to 1939 · 15.5 kW · radiators

Last 30 days

346 hourly rows · MID-class heat meter present: yes
5.01efficiency (COP) over 346 hours, from the heat meter
better than 99% of the metered fleet in January 2026
Electricity used
276 kWh
Heat delivered
1384 kWh (heat meter)
Estimate without heat meter
flow sensor 5.00 · temperature model 5.48
Mean outdoor temperature
13.0 °C · 222 space-heating hours
Flow temperature at 0 °C outside
41.2 °C (curve slope -0.86 per K)
Flow − return while heating
3.3 K
House needs at −3 °C
11.1 kW (unit rated 15.5 kW) · fit r² 0.13
Hot water
18% of electricity, COP 3.23
infoNo configuration faults detected in this window
Keep the current settings. We will alert you if efficiency drifts.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day016322026-10-08: 1.6 kWh, outside 12.8 °C2026-10-09: 9.4 kWh, outside 15.7 °C2026-10-10: 15.4 kWh, outside 13.4 °C2026-10-11: 14.3 kWh, outside 12.9 °C2026-10-12: 8 kWh, outside 16.4 °C2026-10-13: 4 kWh, outside 17.7 °C2026-10-14: 8.4 kWh, outside 14.7 °C2026-10-15: 4.9 kWh, outside 17.4 °C2026-10-16: 5.5 kWh, outside 12.8 °C2026-10-17: 15.7 kWh, outside 10.4 °C2026-10-18: 32.1 kWh, outside 10.1 °C2026-10-19: 23.4 kWh, outside 11 °C2026-10-20: 24.7 kWh, outside 10.9 °C2026-10-21: 21.5 kWh, outside 12 °C2026-10-22: 18.3 kWh, outside 13.5 °C2026-10-23: 24.9 kWh, outside 11.8 °C2026-10-24: 29.3 kWh, outside 12.8 °C2026-10-25: 16 kWh, outside 12.7 °Cdaily COP (heat ÷ electricity)1352026-10-08: COP 4.772026-10-09: COP 3.762026-10-10: COP 5.062026-10-11: COP 5.092026-10-12: COP 5.762026-10-13: COP 4.212026-10-14: COP 4.432026-10-15: COP 5.582026-10-16: COP 6.262026-10-17: COP 5.032026-10-18: COP 4.412026-10-19: COP 5.112026-10-20: COP 5.412026-10-21: COP 5.222026-10-22: COP 52026-10-23: COP 4.962026-10-24: COP 5.082026-10-25: COP 4.9610-0810-1010-1210-1410-1610-1810-2010-2210-24
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
20304050605678910111213141516outdoor temperature, °Cflow temperature, °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.