Home / system #1018

Daikin Altherma 3

Carlton Barnsley · Semi-detached · 109 m² · 1900 to 1939 · 8 kW · underfloor · installed by Damon Blakemore

Last 7 days

169 hourly rows · MID-class heat meter present: yes
3.10efficiency (COP) over 169 hours, from the heat meter
better than 12% of the metered fleet in January 2026
Electricity used
65 kWh
Heat delivered
203 kWh (heat meter)
Estimate without heat meter
flow sensor 2.98 · temperature model 3.66
Mean outdoor temperature
8.8 °C · 33 space-heating hours · cooling 0 kWh removed (0 kWh electricity), kept out of the COP
Flow temperature at 0 °C outside
44.0 °C (curve slope -1.08 per K)
Flow − return while heating
4.3 K
House needs at −3 °C
6.4 kW (unit rated 8 kW) · fit r² 0.00
Hot water
30% of electricity, COP 0.78
infoOnly 33 space-heating hours in this window
Space-heating findings need at least 60 hours with the compressor running below 15 °C outside. Choose a winter window or come back during the heating season.
valueReaching the fleet’s January median (3.69) would have saved about £3 in this window at 0.25 GBP/kWh. An estimate, not a promise.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day05112026-10-31: 6.2 kWh, outside 8.6 °C2026-11-01: 10.6 kWh, outside 7.9 °C2026-11-02: 9.4 kWh, outside 7.9 °C2026-11-03: 8.7 kWh, outside 9.1 °C2026-11-04: 8.9 kWh, outside 9.4 °C2026-11-05: 6.6 kWh, outside 9.3 °C2026-11-06: 9.3 kWh, outside 9.3 °C2026-11-07: 5.9 kWh, outside 7.7 °Cdaily COP (heat ÷ electricity)1352026-10-31: COP 2.72026-11-01: COP 2.542026-11-02: COP 3.312026-11-03: COP 3.32026-11-04: COP 3.422026-11-05: COP 3.072026-11-06: COP 3.252026-11-07: COP 3.0810-3111-0111-0211-0311-0411-0511-0611-07
Daily COP needs a heat meter; days without one show electricity only.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.