Heatproof
Home / system #1153

Grant Aerona HP290

Kenmare, Co Kerry, Ireland · Detached · 240 m² · 1940 to 1982 · 6.5 kW · underfloor · installed by Sean Murphy & Stephen Sinnott

Last 30 days

721 hourly rows · MID-class heat meter present: yes
5.15efficiency (COP) over 721 hours, from the heat meter
better than 99% of the metered fleet in January 2026
Electricity used
246 kWh
Heat delivered
1267 kWh (heat meter)
Estimate without heat meter
flow sensor 5.32 · temperature model 6.05
Mean outdoor temperature
11.8 °C · 319 space-heating hours · cooling 1 kWh removed (0 kWh electricity), kept out of the COP
Flow temperature at 0 °C outside
29.1 °C (curve slope -0.26 per K)
Flow − return while heating
3.0 K
House needs at −3 °C
4.1 kW (unit rated 6.5 kW) · fit r² 0.05
Hot water
31% of electricity, COP 3.93
warningHot water uses 31% of electricity at COP 3.93
Lower the tank target to 45–48 °C, heat water once a day in the warmest hours, and disable weekly legionella cycles unless required.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day07152026-10-08: 1.3 kWh, outside 13.5 °C2026-10-09: 5.5 kWh, outside 14.6 °C2026-10-10: 8.4 kWh, outside 12 °C2026-10-11: 5.7 kWh, outside 13 °C2026-10-12: 3.8 kWh, outside 16.1 °C2026-10-13: 5.1 kWh, outside 14.9 °C2026-10-14: 4.9 kWh, outside 15.7 °C2026-10-15: 5.8 kWh, outside 14.1 °C2026-10-16: 8.3 kWh, outside 11.1 °C2026-10-17: 14.2 kWh, outside 10 °C2026-10-18: 11.7 kWh, outside 8.8 °C2026-10-19: 10.4 kWh, outside 9.1 °C2026-10-20: 9.5 kWh, outside 11.7 °C2026-10-21: 12.5 kWh, outside 10.3 °C2026-10-22: 12.6 kWh, outside 10.4 °C2026-10-23: 13.8 kWh, outside 9.4 °C2026-10-24: 5.8 kWh, outside 11.7 °C2026-10-25: 7.1 kWh, outside 10.3 °C2026-10-26: 6.6 kWh, outside 14 °C2026-10-27: 2.3 kWh, outside 12.3 °C2026-10-28: 8.3 kWh, outside 13.2 °C2026-10-29: 2.4 kWh, outside 13.7 °C2026-10-30: 4.7 kWh, outside 13.7 °C2026-10-31: 2.6 kWh, outside 13.1 °C2026-11-01: 10 kWh, outside 11 °C2026-11-02: 13.7 kWh, outside 10 °C2026-11-03: 14.5 kWh, outside 9.9 °C2026-11-04: 14 kWh, outside 9.8 °C2026-11-05: 8.7 kWh, outside 9.6 °C2026-11-06: 11.6 kWh, outside 9.4 °C2026-11-07: 0.2 kWh, outside 8.6 °Cdaily COP (heat ÷ electricity)1352026-10-08: COP 4.412026-10-09: COP 5.042026-10-10: COP 6.372026-10-11: COP 6.682026-10-12: COP 5.192026-10-13: COP 5.682026-10-14: COP 6.422026-10-15: COP 5.742026-10-16: COP 5.152026-10-17: COP 3.822026-10-18: COP 4.272026-10-19: COP 4.852026-10-20: COP 6.22026-10-21: COP 5.022026-10-22: COP 5.312026-10-23: COP 5.22026-10-24: COP 5.722026-10-25: COP 4.562026-10-26: COP 6.22026-10-27: COP 3.012026-10-28: COP 5.492026-10-29: COP 3.22026-10-30: COP 5.592026-10-31: COP 3.562026-11-01: COP 5.112026-11-02: COP 4.862026-11-03: COP 5.312026-11-04: COP 5.152026-11-05: COP 4.982026-11-06: COP 4.9310-0810-1210-1610-2010-2410-2811-0111-05
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
20304050603579111315outdoor temperature, °Cflow temperature, °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.