Heatproof
Home / system #116

Samsung Gen 6

Deiniolen, Gwynedd · Detached · 133 m² · Pre-1900 · 5 kW · underfloor · installed by OpenEnergyMonitor (designed)

1–31 Dec 2025

745 hourly rows · MID-class heat meter present: yes
4.61efficiency (COP) over 745 hours, from the heat meter
better than 94% of the metered fleet in January 2026
Electricity used
544 kWh
Heat delivered
2511 kWh (heat meter)
Estimate without heat meter
flow sensor 4.70 · temperature model 4.27
Mean outdoor temperature
7.2 °C · 432 space-heating hours · cooling 2 kWh removed (0 kWh electricity), kept out of the COP
Flow temperature at 0 °C outside
31.1 °C (curve slope -0.04 per K)
Flow − return while heating
4.8 K
House needs at −3 °C
4.8 kW (unit rated 5 kW) · fit r² 0.04
Hot water
32% of electricity, COP 4.02
warningHot water uses 32% of electricity at COP 4.02
Lower the tank target to 45–48 °C, heat water once a day in the warmest hours, and disable weekly legionella cycles unless required.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day013262025-12-01: 14.6 kWh, outside 10.6 °C2025-12-02: 17.2 kWh, outside 6.7 °C2025-12-03: 15 kWh, outside 6.3 °C2025-12-04: 17.1 kWh, outside 6.1 °C2025-12-05: 21.9 kWh, outside 6.7 °C2025-12-06: 15.9 kWh, outside 9.6 °C2025-12-07: 11.4 kWh, outside 9.2 °C2025-12-08: 16.7 kWh, outside 10.7 °C2025-12-09: 13.2 kWh, outside 12.3 °C2025-12-10: 13.8 kWh, outside 10 °C2025-12-11: 15.6 kWh, outside 10.6 °C2025-12-12: 12.8 kWh, outside 7.7 °C2025-12-13: 17.5 kWh, outside 8.8 °C2025-12-14: 11 kWh, outside 9.8 °C2025-12-15: 12 kWh, outside 8.3 °C2025-12-16: 18.9 kWh, outside 4.4 °C2025-12-17: 15.8 kWh, outside 8.2 °C2025-12-18: 17 kWh, outside 8.6 °C2025-12-19: 17.9 kWh, outside 8.2 °C2025-12-20: 16.8 kWh, outside 7.4 °C2025-12-21: 18.1 kWh, outside 7.8 °C2025-12-22: 14.7 kWh, outside 8.9 °C2025-12-23: 15.1 kWh, outside 7 °C2025-12-24: 16.4 kWh, outside 4.4 °C2025-12-25: 24 kWh, outside 3.5 °C2025-12-26: 22.1 kWh, outside 3.4 °C2025-12-27: 22.6 kWh, outside 4.7 °C2025-12-28: 25.3 kWh, outside 4.4 °C2025-12-29: 25.7 kWh, outside 3.6 °C2025-12-30: 23.2 kWh, outside 3.8 °C2025-12-31: 24.2 kWh, outside 2 °C2026-01-01: 1.3 kWh, outside 3.5 °Cdaily COP (heat ÷ electricity)1352025-12-01: COP 5.352025-12-02: COP 4.682025-12-03: COP 4.632025-12-04: COP 4.772025-12-05: COP 4.482025-12-06: COP 5.12025-12-07: COP 5.242025-12-08: COP 5.172025-12-09: COP 5.362025-12-10: COP 5.022025-12-11: COP 5.062025-12-12: COP 4.82025-12-13: COP 4.982025-12-14: COP 4.872025-12-15: COP 5.132025-12-16: COP 4.682025-12-17: COP 4.962025-12-18: COP 4.862025-12-19: COP 4.762025-12-20: COP 4.992025-12-21: COP 4.922025-12-22: COP 5.22025-12-23: COP 4.832025-12-24: COP 4.082025-12-25: COP 3.932025-12-26: COP 4.152025-12-27: COP 4.152025-12-28: COP 3.942025-12-29: COP 3.732025-12-30: COP 4.12025-12-31: COP 3.872026-01-01: COP 3.8912-0112-0512-0912-1312-1712-2112-2512-29
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
2030405060-3-113579111315outdoor temperature, °Cflow temperature, °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.