Home / system #1283
Vaillant Arotherm+
Crawley · Detached · 272 m² · 1983 to 2011 · 12 kW · underfloor · installed by Urban Plumbers Ltd
Last 7 days
169 hourly rows · MID-class heat meter present: yes
4.67efficiency (COP) over 169 hours, from the heat meter
better than 95% of the metered fleet in January 2026
better than 95% of the metered fleet in January 2026
- Electricity used
- 170 kWh
- Heat delivered
- 795 kWh (heat meter)
- Estimate without heat meter
- flow sensor 4.37 · temperature model 4.07
- Mean outdoor temperature
- 8.4 °C · 149 space-heating hours
- Flow temperature at 0 °C outside
- 35.9 °C (curve slope -0.31 per K)
- Flow − return while heating
- 1.8 K
- House needs at −3 °C
- 6.2 kW (unit rated 12 kW) · fit r² 0.09
- Hot water
- 20% of electricity, COP 3.89
warningOnly 1.8 K between flow and return
Circulation pump may be set too high or emitters are undersized for the low flow temperature. Ask the installer to check pump speed.
Day by day
electricity per daydaily COP3.0 floor
The installed heating curve
one heating hourfitted curve50 °C