Heatproof
Home / system #1292

LG Therma V

Burgess Hill, West Sussex · Detached · 77 m² · 1983 to 2011 · 7 kW · radiators · installed by PDP

Last 30 days

580 hourly rows · MID-class heat meter present: no
2.73efficiency (COP) over 580 hours, from the heat meter
better than 3% of the metered fleet in January 2026
Electricity used
104 kWh
Heat delivered
283 kWh (heat meter)
Estimate without heat meter
flow sensor – · temperature model –
Mean outdoor temperature
– °C · 167 space-heating hours
Flow temperature at 0 °C outside
–
Flow − return while heating
1.8 K
House needs at −3 °C
–
Hot water
no hot-water flag in data
seriousWinter efficiency 2.73 is below the 3.0 floor used for German subsidies
Ask the installer for a commissioning check; the causes are usually flow temperature, hot water settings, or sizing, all listed below.
warningOnly 1.8 K between flow and return
Circulation pump may be set too high or emitters are undersized for the low flow temperature. Ask the installer to check pump speed.
valueReaching the fleet’s January median (3.69) would have saved about £7 in this window at 0.25 GBP/kWh. An estimate, not a promise.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day0492026-10-08: 2.2 kWh, outside – °C2026-10-09: 2.1 kWh, outside – °C2026-10-10: 3.6 kWh, outside – °C2026-10-11: 4.6 kWh, outside – °C2026-10-12: 1.3 kWh, outside – °C2026-10-13: 3.5 kWh, outside – °C2026-10-14: 2.6 kWh, outside – °C2026-10-15: 2.6 kWh, outside – °C2026-10-16: 2.2 kWh, outside – °C2026-10-17: 3.4 kWh, outside – °C2026-10-18: 5.9 kWh, outside – °C2026-10-19: 6.7 kWh, outside – °C2026-10-20: 5.9 kWh, outside – °C2026-10-21: 6.2 kWh, outside – °C2026-10-22: 6.1 kWh, outside – °C2026-10-23: 5.9 kWh, outside – °C2026-10-24: 8.5 kWh, outside – °C2026-10-25: 6.5 kWh, outside – °C2026-10-26: 5.9 kWh, outside – °C2026-10-27: 4.9 kWh, outside – °C2026-10-28: 6.6 kWh, outside – °C2026-10-29: 4.4 kWh, outside – °C2026-10-30: 0.9 kWh, outside – °C2026-10-31: 0.9 kWh, outside – °C2026-11-01: 0.5 kWh, outside – °Cdaily COP (heat ÷ electricity)1352026-10-08: COP 1.772026-10-09: COP 2.042026-10-10: COP 1.632026-10-11: COP 1.832026-10-12: COP 1.652026-10-13: COP 1.682026-10-14: COP 2.082026-10-15: COP 1.912026-10-16: COP 1.962026-10-17: COP 1.92026-10-18: COP 2.42026-10-19: COP 2.812026-10-20: COP 2.962026-10-21: COP 3.352026-10-22: COP 32026-10-23: COP 3.262026-10-24: COP 3.372026-10-25: COP 3.822026-10-26: COP 3.832026-10-27: COP 2.912026-10-28: COP 3.062026-10-29: COP 2.82026-10-30: COP 02026-10-31: COP 010-0810-1110-1410-1710-2010-2310-2610-2911-01
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.