Home / system #1304
Grant Aerona HP290
Poole, Dorset · Detached · 190 m² · 1940 to 1982 · 15.5 kW · radiators · installed by Octopus Energy Services
Last 7 days
169 hourly rows · MID-class heat meter present: no
5.68efficiency (COP) over 169 hours, from the heat meter
better than 99% of the metered fleet in January 2026
better than 99% of the metered fleet in January 2026
- Electricity used
- 138 kWh
- Heat delivered
- 781 kWh (heat meter)
- Estimate without heat meter
- flow sensor 5.06 · temperature model 4.60
- Mean outdoor temperature
- 10.0 °C · 106 space-heating hours
- Flow temperature at 0 °C outside
- 42.6 °C (curve slope -1.15 per K)
- Flow − return while heating
- 3.0 K
- House needs at −3 °C
- 9.7 kW (unit rated 15.5 kW) · fit r² 0.06
- Hot water
- 34% of electricity, COP 4.44
warningHot water uses 34% of electricity at COP 4.44
Lower the tank target to 45–48 °C, heat water once a day in the warmest hours, and disable weekly legionella cycles unless required.
Day by day
electricity per daydaily COP3.0 floor
The installed heating curve
one heating hourfitted curve50 °C
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.