Home / system #1373
Vaillant Arotherm+
North Scarle, Lincoln · Bungalow · 100 m² · 1983 to 2011 · 7 kW · radiators · installed by GlowGroup
Last 7 days
169 hourly rows · MID-class heat meter present: no
4.52efficiency (COP) over 169 hours, from the heat meter
better than 93% of the metered fleet in January 2026
better than 93% of the metered fleet in January 2026
- Electricity used
- 57 kWh
- Heat delivered
- 259 kWh (heat meter)
- Estimate without heat meter
- flow sensor 0.00 · temperature model –
- Mean outdoor temperature
- – °C · 94 space-heating hours · cooling 5 kWh removed (0 kWh electricity), kept out of the COP
- Flow temperature at 0 °C outside
- –
- Flow − return while heating
- 1.8 K
- House needs at −3 °C
- –
- Hot water
- no hot-water flag in data
warningOnly 1.8 K between flow and return
Circulation pump may be set too high or emitters are undersized for the low flow temperature. Ask the installer to check pump speed.
noteOwner’s note on the source site: “flow rate being detected when heat pump is off”
Day by day
electricity per daydaily COP3.0 floor
The installed heating curve
one heating hourfitted curve50 °C
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.