Heatproof
Home / system #1381

Vaillant Arotherm+

Rhigos, Rhondda Cynon Taf · Bungalow · 190 m² · 2012 or newer · 5 kW · underfloor · installed by Net Zero Heating Solutions

Last 30 days

721 hourly rows · MID-class heat meter present: yes
4.72efficiency (COP) over 721 hours, from the heat meter
better than 97% of the metered fleet in January 2026
Electricity used
283 kWh
Heat delivered
1338 kWh (heat meter)
Estimate without heat meter
flow sensor 4.71 · temperature model 4.51
Mean outdoor temperature
10.1 °C · 379 space-heating hours · cooling 5 kWh removed (0 kWh electricity), kept out of the COP
Flow temperature at 0 °C outside
33.8 °C (curve slope -0.52 per K)
Flow − return while heating
2.7 K
House needs at −3 °C
4.3 kW (unit rated 5 kW) · fit r² 0.06
Hot water
24% of electricity, COP 3.73
warningOnly 2.7 K between flow and return
Circulation pump may be set too high or emitters are undersized for the low flow temperature. Ask the installer to check pump speed.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day010202026-10-08: 2.2 kWh, outside 12.1 °C2026-10-09: 4.1 kWh, outside 13.9 °C2026-10-10: 6 kWh, outside 10.7 °C2026-10-11: 7.3 kWh, outside 11.1 °C2026-10-12: 3.3 kWh, outside 15.9 °C2026-10-13: 3.8 kWh, outside 14.4 °C2026-10-14: 6 kWh, outside 12.7 °C2026-10-15: 2.2 kWh, outside 15.2 °C2026-10-16: 9.1 kWh, outside 9.2 °C2026-10-17: 11 kWh, outside 6.4 °C2026-10-18: 15.1 kWh, outside 7.6 °C2026-10-19: 4.7 kWh, outside 8.8 °C2026-10-20: 19.6 kWh, outside 7.5 °C2026-10-21: 14 kWh, outside 8.4 °C2026-10-22: 10.1 kWh, outside 9.9 °C2026-10-23: 10.7 kWh, outside 8.8 °C2026-10-24: 10 kWh, outside 10.2 °C2026-10-25: 11.7 kWh, outside 9.7 °C2026-10-26: 7.2 kWh, outside 12.1 °C2026-10-27: 3.3 kWh, outside 11.3 °C2026-10-28: 8.8 kWh, outside 11.3 °C2026-10-29: 7.7 kWh, outside 11.1 °C2026-10-30: 7.8 kWh, outside 10.8 °C2026-10-31: 6.5 kWh, outside 7.8 °C2026-11-01: 10.1 kWh, outside 8.3 °C2026-11-02: 8.8 kWh, outside 8.1 °C2026-11-03: 11.8 kWh, outside 8.5 °C2026-11-04: 12.9 kWh, outside 8.7 °C2026-11-05: 14.1 kWh, outside 7.6 °C2026-11-06: 18.5 kWh, outside 7.7 °C2026-11-07: 15 kWh, outside 6.1 °Cdaily COP (heat ÷ electricity)1352026-10-08: COP 5.732026-10-09: COP 5.432026-10-10: COP 5.342026-10-11: COP 5.022026-10-12: COP 4.892026-10-13: COP 5.672026-10-14: COP 5.362026-10-15: COP 4.772026-10-16: COP 5.332026-10-17: COP 4.692026-10-18: COP 4.032026-10-19: COP 4.412026-10-20: COP 3.822026-10-21: COP 4.242026-10-22: COP 4.812026-10-23: COP 5.362026-10-24: COP 5.192026-10-25: COP 4.982026-10-26: COP 5.012026-10-27: COP 5.62026-10-28: COP 5.62026-10-29: COP 5.552026-10-30: COP 4.322026-10-31: COP 5.312026-11-01: COP 5.132026-11-02: COP 4.992026-11-03: COP 5.182026-11-04: COP 4.992026-11-05: COP 4.782026-11-06: COP 3.392026-11-07: COP 3.2610-0810-1210-1610-2010-2410-2811-0111-05
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
20304050600246810121416outdoor temperature, °Cflow temperature, °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.