Heatproof
Home / system #1381

Vaillant Arotherm+

Rhigos, Rhondda Cynon Taf · Bungalow · 190 m² · 2012 or newer · 5 kW · underfloor · installed by Net Zero Heating Solutions

Last 7 days

169 hourly rows · MID-class heat meter present: yes
4.44efficiency (COP) over 169 hours, from the heat meter
better than 92% of the metered fleet in January 2026
Electricity used
95 kWh
Heat delivered
420 kWh (heat meter)
Estimate without heat meter
flow sensor 4.48 · temperature model 4.25
Mean outdoor temperature
8.1 °C · 117 space-heating hours · cooling 1 kWh removed (0 kWh electricity), kept out of the COP
Flow temperature at 0 °C outside
36.5 °C (curve slope -0.86 per K)
Flow − return while heating
2.9 K
House needs at −3 °C
6.5 kW (unit rated 5 kW) · fit r² 0.10
Hot water
23% of electricity, COP 3.63
warningOnly 2.9 K between flow and return
Circulation pump may be set too high or emitters are undersized for the low flow temperature. Ask the installer to check pump speed.
warningUnit is rated 5 kW but the house needs about 6.5 kW at −3 °C
Expect backup heater use on the coldest days. Improve insulation or draught-proofing before adding capacity.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day09192026-10-31: 3.2 kWh, outside 8.6 °C2026-11-01: 10.1 kWh, outside 8.3 °C2026-11-02: 8.8 kWh, outside 8.1 °C2026-11-03: 11.8 kWh, outside 8.5 °C2026-11-04: 12.9 kWh, outside 8.7 °C2026-11-05: 14.1 kWh, outside 7.6 °C2026-11-06: 18.5 kWh, outside 7.7 °C2026-11-07: 15.3 kWh, outside 6 °Cdaily COP (heat ÷ electricity)1352026-10-31: COP 5.372026-11-01: COP 5.132026-11-02: COP 4.992026-11-03: COP 5.182026-11-04: COP 4.992026-11-05: COP 4.782026-11-06: COP 3.392026-11-07: COP 3.2910-3111-0111-0211-0311-0411-0511-0611-07
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
20304050603456789101112outdoor temperature, °Cflow temperature, °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.