Sunrain SMHP-006C1
Dublin, Ireland · Semi-detached · 115 m² · 2012 or newer · 6 kW · radiators · installed by Self-install
Last 7 days
168 hourly rows · MID-class heat meter present: yes
4.13efficiency (COP) over 168 hours, from the heat meter
better than 84% of the metered fleet in January 2026
better than 84% of the metered fleet in January 2026
- Electricity used
- 48 kWh
- Heat delivered
- 199 kWh (heat meter)
- Estimate without heat meter
- flow sensor 3.76 · temperature model 4.62
- Mean outdoor temperature
- 9.9 °C · 82 space-heating hours
- Flow temperature at 0 °C outside
- 38.6 °C (curve slope -0.81 per K)
- Flow − return while heating
- 1.7 K
- House needs at −3 °C
- 3.2 kW (unit rated 6 kW) · fit r² 0.29
- Hot water
- 30% of electricity, COP 3.91
warningOnly 1.7 K between flow and return
Circulation pump may be set too high or emitters are undersized for the low flow temperature. Ask the installer to check pump speed.
noteOwner’s note on the source site: “No negative heat during defrost, require proof of MID heat meter”
Day by day
electricity per daydaily COP3.0 floor
The installed heating curve
one heating hourfitted curve50 °C