Daikin Altherma 3

Dundee · Semi-detached · 102 m² · 2012 or newer · 6 kW · radiators · installed by The Natural Energy Company

Last 7 days

169 hourly rows · MID-class heat meter present: yes
3.23efficiency (COP) over 169 hours, from the heat meter
better than 24% of the metered fleet in January 2026
Electricity used
60 kWh
Heat delivered
195 kWh (heat meter)
Estimate without heat meter
flow sensor 3.20 · temperature model 3.45
Mean outdoor temperature
7.4 °C · 58 space-heating hours
Flow temperature at 0 °C outside
39.4 °C (curve slope 0.16 per K)
Flow − return while heating
5.0 K
House needs at −3 °C
1.6 kW (unit rated 6 kW) · fit r² 0.14
Hot water
no hot-water flag in data
infoOnly 58 space-heating hours in this window
Space-heating findings need at least 60 hours with the compressor running below 15 °C outside. Choose a winter window or come back during the heating season.
noteOwner’s note on the source site: “Negative heat not reported”
valueReaching the fleet’s January median (3.69) would have saved about £2 in this window at 0.25 GBP/kWh. An estimate, not a promise.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day05112026-10-31: 4.2 kWh, outside 11.4 °C2026-11-01: 7.6 kWh, outside 8.5 °C2026-11-02: 10.5 kWh, outside 4.8 °C2026-11-03: 9.2 kWh, outside 7.9 °C2026-11-04: 8.9 kWh, outside 6 °C2026-11-05: 8.4 kWh, outside 6.5 °C2026-11-06: 8.7 kWh, outside 7.9 °C2026-11-07: 2.8 kWh, outside 7.2 °Cdaily COP (heat ÷ electricity)1352026-10-31: COP 3.912026-11-01: COP 3.082026-11-02: COP 3.012026-11-03: COP 3.32026-11-04: COP 3.362026-11-05: COP 3.082026-11-06: COP 3.22026-11-07: COP 3.3910-3111-0111-0211-0311-0411-0511-0611-07
Daily COP needs a heat meter; days without one show electricity only.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.