Home / system #441
Panasonic Aquarea M
Thurso · Detached · 300 m² · 1983 to 2011 · 9 kW · underfloor · installed by RDI Renewables
Last 7 days
169 hourly rows · MID-class heat meter present: yes
4.58efficiency (COP) over 169 hours, from the heat meter
better than 94% of the metered fleet in January 2026
better than 94% of the metered fleet in January 2026
- Electricity used
- 180 kWh
- Heat delivered
- 825 kWh (heat meter)
- Estimate without heat meter
- flow sensor 4.49 · temperature model 3.43
- Mean outdoor temperature
- 4.5 °C · 85 space-heating hours · cooling 0 kWh removed (1 kWh electricity), kept out of the COP
- Flow temperature at 0 °C outside
- 31.0 °C (curve slope -0.26 per K)
- Flow − return while heating
- 3.1 K
- House needs at −3 °C
- 8.2 kW (unit rated 9 kW) · fit r² 0.08
- Hot water
- 47% of electricity, COP 3.19
warningHot water uses 47% of electricity at COP 3.19
Lower the tank target to 45–48 °C, heat water once a day in the warmest hours, and disable weekly legionella cycles unless required.
noteOwner’s note on the source site: “does this system have a booster heater”
Day by day
electricity per daydaily COP3.0 floor
The installed heating curve
one heating hourfitted curve50 °C
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.