Heatproof
Home / system #560

Nibe F1145

Hereford · Detached · 120 m² · Pre-1900 · 12 kW · radiators · installed by Lloyd R

Last 30 days

721 hourly rows · MID-class heat meter present: no
3.71efficiency (COP) over 721 hours, from the heat meter
better than 55% of the metered fleet in January 2026
Electricity used
234 kWh
Heat delivered
869 kWh (heat meter)
Estimate without heat meter
flow sensor 0.00 · temperature model –
Mean outdoor temperature
– °C · 284 space-heating hours · cooling 2 kWh removed (5 kWh electricity), kept out of the COP
Flow temperature at 0 °C outside
–
Flow − return while heating
2.2 K
House needs at −3 °C
–
Hot water
28% of electricity, COP 3.43
warningOnly 2.2 K between flow and return
Circulation pump may be set too high or emitters are undersized for the low flow temperature. Ask the installer to check pump speed.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day06122026-10-08: 1.7 kWh, outside – °C2026-10-09: 4.2 kWh, outside – °C2026-10-10: 4.4 kWh, outside – °C2026-10-11: 5.8 kWh, outside – °C2026-10-12: 1.8 kWh, outside – °C2026-10-13: 2.3 kWh, outside – °C2026-10-14: 3.8 kWh, outside – °C2026-10-15: 2.9 kWh, outside – °C2026-10-16: 4.1 kWh, outside – °C2026-10-17: 7 kWh, outside – °C2026-10-18: 11 kWh, outside – °C2026-10-19: 9.2 kWh, outside – °C2026-10-20: 12.3 kWh, outside – °C2026-10-21: 9.9 kWh, outside – °C2026-10-22: 8.5 kWh, outside – °C2026-10-23: 10 kWh, outside – °C2026-10-24: 11.9 kWh, outside – °C2026-10-25: 11.4 kWh, outside – °C2026-10-26: 7.7 kWh, outside – °C2026-10-27: 7.2 kWh, outside – °C2026-10-28: 7.5 kWh, outside – °C2026-10-29: 7.3 kWh, outside – °C2026-10-30: 8.7 kWh, outside – °C2026-10-31: 10.8 kWh, outside – °C2026-11-01: 9 kWh, outside – °C2026-11-02: 9.8 kWh, outside – °C2026-11-03: 11.5 kWh, outside – °C2026-11-04: 10.6 kWh, outside – °C2026-11-05: 12.2 kWh, outside – °C2026-11-06: 9.6 kWh, outside – °C2026-11-07: 5 kWh, outside – °Cdaily COP (heat ÷ electricity)1352026-10-08: COP 2.512026-10-09: COP 2.852026-10-10: COP 3.262026-10-11: COP 2.782026-10-12: COP 1.582026-10-13: COP 0.22026-10-14: COP 2.222026-10-15: COP 1.412026-10-16: COP 2.512026-10-17: COP 3.912026-10-18: COP 4.032026-10-19: COP 3.982026-10-20: COP 3.962026-10-21: COP 3.982026-10-22: COP 3.872026-10-23: COP 3.892026-10-24: COP 3.952026-10-25: COP 3.792026-10-26: COP 3.712026-10-27: COP 3.652026-10-28: COP 3.572026-10-29: COP 3.732026-10-30: COP 3.692026-10-31: COP 3.892026-11-01: COP 3.632026-11-02: COP 3.762026-11-03: COP 3.812026-11-04: COP 3.772026-11-05: COP 3.792026-11-06: COP 3.712026-11-07: COP 3.8210-0810-1210-1610-2010-2410-2811-0111-05
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.