Heatproof
Home / system #752

Vaillant Arotherm+

Cardiff · Semi-detached · 250 m² · 1900 to 1939 · 10 kW · radiators · installed by WDS green energy

Last 7 days

169 hourly rows · MID-class heat meter present: yes
4.30efficiency (COP) over 169 hours, from the heat meter
better than 91% of the metered fleet in January 2026
Electricity used
97 kWh
Heat delivered
418 kWh (heat meter)
Estimate without heat meter
flow sensor 3.85 · temperature model 4.14
Mean outdoor temperature
8.1 °C · 78 space-heating hours
Flow temperature at 0 °C outside
28.4 °C (curve slope -0.07 per K)
Flow − return while heating
1.6 K
House needs at −3 °C
5.2 kW (unit rated 10 kW) · fit r² 0.01
Hot water
44% of electricity, COP 3.20
warningOnly 1.6 K between flow and return
Circulation pump may be set too high or emitters are undersized for the low flow temperature. Ask the installer to check pump speed.
warningHot water uses 44% of electricity at COP 3.2
Lower the tank target to 45–48 °C, heat water once a day in the warmest hours, and disable weekly legionella cycles unless required.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day09182026-10-31: 5 kWh, outside 9.2 °C2026-11-01: 11.8 kWh, outside 8.4 °C2026-11-02: 7.7 kWh, outside 8.3 °C2026-11-03: 14 kWh, outside 7.8 °C2026-11-04: 15.3 kWh, outside 8.3 °C2026-11-05: 18.3 kWh, outside 7.4 °C2026-11-06: 16.1 kWh, outside 7.7 °C2026-11-07: 9.3 kWh, outside 7.1 °Cdaily COP (heat ÷ electricity)1352026-10-31: COP 3.752026-11-01: COP 3.842026-11-02: COP 4.512026-11-03: COP 4.862026-11-04: COP 4.242026-11-05: COP 4.072026-11-06: COP 4.432026-11-07: COP 4.410-3111-0111-0211-0311-0411-0511-0611-07
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
2030405060345678910111213outdoor temperature, °Cflow temperature, °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.