Home / system #812
Vaillant Arotherm+
Hove, East Sussex · Detached · 118 m² · 1940 to 1982 · 5 kW · radiators · installed by Hartswood
Last 7 days
169 hourly rows · MID-class heat meter present: yes
4.56efficiency (COP) over 169 hours, from the heat meter
better than 94% of the metered fleet in January 2026
better than 94% of the metered fleet in January 2026
- Electricity used
- 80 kWh
- Heat delivered
- 367 kWh (heat meter)
- Estimate without heat meter
- flow sensor 4.61 · temperature model 4.20
- Mean outdoor temperature
- 8.8 °C · 75 space-heating hours
- Flow temperature at 0 °C outside
- 37.5 °C (curve slope -0.54 per K)
- Flow − return while heating
- 3.8 K
- House needs at −3 °C
- 8.2 kW (unit rated 5 kW) · fit r² 0.50
- Hot water
- 24% of electricity, COP 3.57
warningUnit is rated 5 kW but the house needs about 8.2 kW at −3 °C
Expect backup heater use on the coldest days. Improve insulation or draught-proofing before adding capacity.
Day by day
electricity per daydaily COP3.0 floor
The installed heating curve
one heating hourfitted curve50 °C
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.