Heatproof
Home / system #917

Test Unit R290

Basingstoke · Semi-detached · 120 m² · 1940 to 1982 · 9 kW · underfloor · installed by Next Climate Consultant

1–31 Dec 2025

6 hourly rows · MID-class heat meter present: no
2.25efficiency (COP) over 6 hours, from the heat meter
better than 1% of the metered fleet in January 2026
Electricity used
9 kWh
Heat delivered
21 kWh (heat meter)
Estimate without heat meter
flow sensor 2.28 · temperature model 2.98
Mean outdoor temperature
-1.3 °C · 6 space-heating hours
Flow temperature at 0 °C outside
32.5 °C (curve slope -1.24 per K)
Flow − return while heating
2.0 K
House needs at −3 °C
4.5 kW (unit rated 9 kW) · fit r² 0.06
Hot water
no hot-water flag in data
infoOnly 6 space-heating hours in this window
Space-heating findings need at least 60 hours with the compressor running below 15 °C outside. Choose a winter window or come back during the heating season.
valueReaching the fleet’s January median (3.69) would have saved about £1 in this window at 0.25 GBP/kWh. An estimate, not a promise.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day0482025-12-31: 7.8 kWh, outside -1.2 °C2026-01-01: 1.3 kWh, outside -2 °Cdaily COP (heat ÷ electricity)1352025-12-31: COP 2.262026-01-01: COP 2.212-3101-01
Daily COP needs a heat meter; days without one show electricity only.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.