Home / system #1086
Heliotherm Comfort Compact
Richmond · Detached · 630 m² · 1900 to 1939 · 18 kW · underfloor · installed by Urban Plumbers Ltd
Last 7 days
169 hourly rows · MID-class heat meter present: yes
4.74efficiency (COP) over 169 hours, from the heat meter
better than 97% of the metered fleet in January 2026
better than 97% of the metered fleet in January 2026
- Electricity used
- 218 kWh
- Heat delivered
- 1031 kWh (heat meter)
- Estimate without heat meter
- flow sensor 4.88 · temperature model 5.12
- Mean outdoor temperature
- 9.2 °C · 120 space-heating hours · cooling 5 kWh removed (1 kWh electricity), kept out of the COP
- Flow temperature at 0 °C outside
- 29.2 °C (curve slope 0.05 per K)
- Flow − return while heating
- 3.4 K
- House needs at −3 °C
- 9.1 kW (unit rated 18 kW) · fit r² 0.00
- Hot water
- no hot-water flag in data
infoNo configuration faults detected in this window
Keep the current settings. We will alert you if efficiency drifts.
Day by day
electricity per daydaily COP3.0 floor
The installed heating curve
one heating hourfitted curve50 °C