Viessmann Vitocal 150A

Bentlawnt, Shropshire · Detached · 140 m² · 2012 or newer · 10 kW · underfloor · installed by Josh Stead

Last 7 days

73 hourly rows · MID-class heat meter present: yes
5.27efficiency (COP) over 73 hours, from the heat meter
better than 99% of the metered fleet in January 2026
Electricity used
44 kWh
Heat delivered
229 kWh (heat meter)
Estimate without heat meter
flow sensor 5.34 · temperature model 4.44
Mean outdoor temperature
7.9 °C · 57 space-heating hours · cooling 0 kWh removed (0 kWh electricity), kept out of the COP
Flow temperature at 0 °C outside
30.6 °C (curve slope -0.01 per K)
Flow − return while heating
3.8 K
House needs at −3 °C
2.8 kW (unit rated 10 kW) · fit r² 0.00
Hot water
16% of electricity, COP 4.38
infoOnly 57 space-heating hours in this window
Space-heating findings need at least 60 hours with the compressor running below 15 °C outside. Choose a winter window or come back during the heating season.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day08152026-11-04: 8.2 kWh, outside 9.1 °C2026-11-05: 15.2 kWh, outside 7.9 °C2026-11-06: 13.9 kWh, outside 7.9 °C2026-11-07: 6.3 kWh, outside 6 °Cdaily COP (heat ÷ electricity)1352026-11-04: COP 5.492026-11-05: COP 5.072026-11-06: COP 5.242026-11-07: COP 5.4111-0411-0511-0611-07
Daily COP needs a heat meter; days without one show electricity only.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.