Home / system #1412
Daikin Altherma 3
Erts, Andorra · Flat / appartment · 67 m² · 2012 or newer · 14 kW · underfloor
Last 7 days
169 hourly rows · MID-class heat meter present: no
3.25efficiency (COP) over 169 hours, from the heat meter
better than 24% of the metered fleet in January 2026
better than 24% of the metered fleet in January 2026
- Electricity used
- 39 kWh
- Heat delivered
- 127 kWh (heat meter)
- Estimate without heat meter
- flow sensor 3.28 · temperature model 4.38
- Mean outdoor temperature
- 3.1 °C · 43 space-heating hours · cooling 1 kWh removed (0 kWh electricity), kept out of the COP
- Flow temperature at 0 °C outside
- 26.8 °C (curve slope 0.13 per K)
- Flow − return while heating
- 2.4 K
- House needs at −3 °C
- 1.1 kW (unit rated 14 kW) · fit r² 0.36
- Hot water
- 20% of electricity, COP 3.01
infoOnly 43 space-heating hours in this window
Space-heating findings need at least 60 hours with the compressor running below 15 °C outside. Choose a winter window or come back during the heating season.
valueReaching the fleet’s January median (3.69) would have saved about £1 in this window at 0.25 GBP/kWh. An estimate, not a promise.
Day by day
electricity per daydaily COP3.0 floor
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.