721 hourly rows · MID-class heat meter present: yes
4.10efficiency (COP) over 721 hours, from the heat meter better than 81% of the metered fleet in January 2026
Electricity used
54 kWh
Heat delivered
223 kWh (heat meter)
Estimate without heat meter
flow sensor 3.13 · temperature model 10.13
Mean outdoor temperature
12.6 °C · 32 space-heating hours · cooling 0 kWh removed (0 kWh electricity), kept out of the COP
Flow temperature at 0 °C outside
34.4 °C (curve slope -0.35 per K)
Flow − return while heating
1.6 K
House needs at −3 °C
2.1 kW (unit rated 7 kW) · fit r² 0.02
Hot water
11% of electricity, COP 0.44
infoOnly 32 space-heating hours in this window
Space-heating findings need at least 60 hours with the compressor running below 15 °C outside. Choose a winter window or come back during the heating season.
noteOwner’s note on the source site: “No heat on hot water due to split system”
Day by day
electricity per daydaily COP3.0 floor
Daily COP needs a heat meter; days without one show electricity only.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.