Home / system #421
Daikin Altherma 2
Horsham, West Sussex · Detached · 128 m² · 1983 to 2011 · 7 kW · radiators · installed by Octopus Energy Services
Last 7 days
168 hourly rows · MID-class heat meter present: no
3.76efficiency (COP) over 168 hours, from the heat meter
better than 59% of the metered fleet in January 2026
better than 59% of the metered fleet in January 2026
- Electricity used
- 92 kWh
- Heat delivered
- 345 kWh (heat meter)
- Estimate without heat meter
- flow sensor 3.81 · temperature model 4.05
- Mean outdoor temperature
- 9.4 °C · 132 space-heating hours
- Flow temperature at 0 °C outside
- 38.1 °C (curve slope -0.39 per K)
- Flow − return while heating
- 3.5 K
- House needs at −3 °C
- 3.8 kW (unit rated 7 kW) · fit r² 0.16
- Hot water
- 12% of electricity, COP 2.61
infoNo configuration faults detected in this window
Keep the current settings. We will alert you if efficiency drifts.
Day by day
electricity per daydaily COP3.0 floor
The installed heating curve
one heating hourfitted curve50 °C
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.