Daikin Altherma 3
Manchester · Detached · 117 m² · 2012 or newer · 8 kW · radiators · installed by Octopus Energy Services
1–31 Dec 2025
391 hourly rows · MID-class heat meter present: no
1.64efficiency (COP) over 391 hours, from the heat meter
better than 1% of the metered fleet in January 2026
better than 1% of the metered fleet in January 2026
- Electricity used
- 358 kWh
- Heat delivered
- 588 kWh (heat meter)
- Estimate without heat meter
- flow sensor 1.67 · temperature model 3.32
- Mean outdoor temperature
- 7.6 °C · 328 space-heating hours
- Flow temperature at 0 °C outside
- 42.6 °C (curve slope -0.46 per K)
- Flow − return while heating
- 5.2 K
- House needs at −3 °C
- 6.2 kW (unit rated 8 kW) · fit r² 0.07
- Hot water
- 10% of electricity, COP 3.57
seriousWinter efficiency 1.64 is below the 3.0 floor used for German subsidies
Ask the installer for a commissioning check; the causes are usually flow temperature, hot water settings, or sizing, all listed below.
noteOwner’s note on the source site: “No data”
valueReaching the fleet’s January median (3.69) would have saved about £50 in this window at 0.25 GBP/kWh. An estimate, not a promise.
Day by day
electricity per daydaily COP3.0 floor
The installed heating curve
one heating hourfitted curve50 °C
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.