Heatproof
Home / system #88

Stiebel Eltron WPL25-AS

Lichfield, UK · Detached · 202 m² · 1940 to 1982 · 12.5 kW · underfloor · installed by Niche Energy Systems Ltd

1–31 Dec 2025

745 hourly rows · MID-class heat meter present: no
2.03efficiency (COP) over 745 hours, from the heat meter
better than 1% of the metered fleet in January 2026
Electricity used
1910 kWh
Heat delivered
3879 kWh (heat meter)
Estimate without heat meter
flow sensor 2.05 · temperature model 4.06
Mean outdoor temperature
6.7 °C · 745 space-heating hours
Flow temperature at 0 °C outside
39.6 °C (curve slope -0.69 per K)
Flow − return while heating
5.0 K
House needs at −3 °C
8.0 kW (unit rated 12.5 kW) · fit r² 0.04
Hot water
no hot-water flag in data
seriousWinter efficiency 2.03 is below the 3.0 floor used for German subsidies
Ask the installer for a commissioning check; the causes are usually flow temperature, hot water settings, or sizing, all listed below.
valueReaching the fleet’s January median (3.69) would have saved about £215 in this window at 0.25 GBP/kWh. An estimate, not a promise.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day031622025-12-01: 61.5 kWh, outside 9.9 °C2025-12-02: 61.5 kWh, outside 5.6 °C2025-12-03: 61.5 kWh, outside 4.4 °C2025-12-04: 61.5 kWh, outside 6.4 °C2025-12-05: 61.5 kWh, outside 4.5 °C2025-12-06: 61.5 kWh, outside 8.7 °C2025-12-07: 61.5 kWh, outside 8.7 °C2025-12-08: 61.5 kWh, outside 8.5 °C2025-12-09: 61.5 kWh, outside 11.7 °C2025-12-10: 61.5 kWh, outside 8.6 °C2025-12-11: 61.5 kWh, outside 8 °C2025-12-12: 61.5 kWh, outside 8 °C2025-12-13: 61.5 kWh, outside 4.8 °C2025-12-14: 61.5 kWh, outside 8.8 °C2025-12-15: 61.5 kWh, outside 10.3 °C2025-12-16: 61.5 kWh, outside 6.6 °C2025-12-17: 61.5 kWh, outside 6.1 °C2025-12-18: 61.5 kWh, outside 8.9 °C2025-12-19: 61.5 kWh, outside 5.1 °C2025-12-20: 61.5 kWh, outside 4.5 °C2025-12-21: 61.5 kWh, outside 7.9 °C2025-12-22: 61.5 kWh, outside 8.9 °C2025-12-23: 61.5 kWh, outside 7 °C2025-12-24: 61.5 kWh, outside 5 °C2025-12-25: 61.5 kWh, outside 3.8 °C2025-12-26: 61.5 kWh, outside 2.6 °C2025-12-27: 61.5 kWh, outside 4.6 °C2025-12-28: 61.5 kWh, outside 6 °C2025-12-29: 61.5 kWh, outside 5.7 °C2025-12-30: 61.5 kWh, outside 4.8 °C2025-12-31: 61.5 kWh, outside 2 °C2026-01-01: 2.6 kWh, outside 3.7 °Cdaily COP (heat ÷ electricity)1352025-12-01: COP 1.542025-12-02: COP 2.212025-12-03: COP 2.382025-12-04: COP 2.082025-12-05: COP 2.262025-12-06: COP 1.742025-12-07: COP 1.722025-12-08: COP 1.722025-12-09: COP 1.22025-12-10: COP 1.592025-12-11: COP 1.642025-12-12: COP 1.742025-12-13: COP 2.182025-12-14: COP 1.672025-12-15: COP 1.512025-12-16: COP 1.922025-12-17: COP 2.142025-12-18: COP 1.712025-12-19: COP 2.152025-12-20: COP 2.212025-12-21: COP 1.842025-12-22: COP 1.732025-12-23: COP 1.962025-12-24: COP 2.472025-12-25: COP 2.642025-12-26: COP 2.92025-12-27: COP 2.392025-12-28: COP 2.192025-12-29: COP 2.292025-12-30: COP 2.332025-12-31: COP 2.772026-01-01: COP 4.3612-0112-0512-0912-1312-1712-2112-2512-29
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
2030405060-202468101214outdoor temperature, °Cflow temperature, °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.