Heatproof
Home / system #167

Nibe F2050

Cadross, Dumbarton · Detached · 123 m² · Pre-1900 · 10 kW · radiators · installed by Renewable Heat

1–31 Dec 2025

745 hourly rows · MID-class heat meter present: yes
4.12efficiency (COP) over 745 hours, from the heat meter
better than 84% of the metered fleet in January 2026
Electricity used
638 kWh
Heat delivered
2628 kWh (heat meter)
Estimate without heat meter
flow sensor 4.37 · temperature model 3.47
Mean outdoor temperature
6.6 °C · 744 space-heating hours
Flow temperature at 0 °C outside
42.3 °C (curve slope -0.84 per K)
Flow − return while heating
4.6 K
House needs at −3 °C
5.5 kW (unit rated 10 kW) · fit r² 0.41
Hot water
no hot-water flag in data
infoNo configuration faults detected in this window
Keep the current settings. We will alert you if efficiency drifts.
noteOwner’s note on the source site: “Unchecked primary circ pump flow rate change without visible pump power change”

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day023462025-12-01: 16.7 kWh, outside 8.2 °C2025-12-02: 17.3 kWh, outside 6.8 °C2025-12-03: 20.8 kWh, outside 5.9 °C2025-12-04: 17.5 kWh, outside 6.7 °C2025-12-05: 20.2 kWh, outside 5.3 °C2025-12-06: 17.4 kWh, outside 7.7 °C2025-12-07: 13.8 kWh, outside 8.3 °C2025-12-08: 13.4 kWh, outside 8.8 °C2025-12-09: 11.3 kWh, outside 10.9 °C2025-12-10: 13.3 kWh, outside 9.8 °C2025-12-11: 12.7 kWh, outside 10.4 °C2025-12-12: 15.5 kWh, outside 6.5 °C2025-12-13: 15.3 kWh, outside 8.4 °C2025-12-14: 9.3 kWh, outside 11.5 °C2025-12-15: 17.9 kWh, outside 6 °C2025-12-16: 28.7 kWh, outside 2.9 °C2025-12-17: 18.6 kWh, outside 8.6 °C2025-12-18: 19.3 kWh, outside 7.6 °C2025-12-19: 19.9 kWh, outside 7.7 °C2025-12-20: 21.7 kWh, outside 6.6 °C2025-12-21: 20.9 kWh, outside 7.4 °C2025-12-22: 15.4 kWh, outside 8.6 °C2025-12-23: 17.7 kWh, outside 7 °C2025-12-24: 22.2 kWh, outside 4.9 °C2025-12-25: 26.1 kWh, outside 3.2 °C2025-12-26: 25.1 kWh, outside 3.1 °C2025-12-27: 30.5 kWh, outside 4.9 °C2025-12-28: 27.5 kWh, outside 4.8 °C2025-12-29: 33.1 kWh, outside 3.1 °C2025-12-30: 45.8 kWh, outside -0.3 °C2025-12-31: 32.4 kWh, outside 4.2 °C2026-01-01: 1.2 kWh, outside 7 °Cdaily COP (heat ÷ electricity)1352025-12-01: COP 4.692025-12-02: COP 4.52025-12-03: COP 4.222025-12-04: COP 4.552025-12-05: COP 4.162025-12-06: COP 4.592025-12-07: COP 4.942025-12-08: COP 4.962025-12-09: COP 5.172025-12-10: COP 4.892025-12-11: COP 5.042025-12-12: COP 4.52025-12-13: COP 4.792025-12-14: COP 62025-12-15: COP 4.222025-12-16: COP 3.472025-12-17: COP 4.672025-12-18: COP 4.552025-12-19: COP 4.472025-12-20: COP 4.232025-12-21: COP 4.292025-12-22: COP 4.82025-12-23: COP 4.492025-12-24: COP 4.052025-12-25: COP 3.852025-12-26: COP 3.942025-12-27: COP 3.572025-12-28: COP 3.662025-12-29: COP 3.32025-12-30: COP 2.652025-12-31: COP 3.482026-01-01: COP 3.6212-0112-0512-0912-1312-1712-2112-2512-29
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
2030405060-5-2147101316outdoor temperature, °Cflow temperature, °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.