Heatproof
Home / system #167

Nibe F2050

Cadross, Dumbarton · Detached · 123 m² · Pre-1900 · 10 kW · radiators · installed by Renewable Heat

5 Jan – 4 Feb 2026 (winter reference)

715 hourly rows · MID-class heat meter present: yes
3.48efficiency (COP) over 715 hours, from the heat meter
better than 37% of the metered fleet in January 2026
Electricity used
917 kWh
Heat delivered
3191 kWh (heat meter)
Estimate without heat meter
flow sensor 3.73 · temperature model 3.04
Mean outdoor temperature
4.8 °C · 715 space-heating hours
Flow temperature at 0 °C outside
43.7 °C (curve slope -0.77 per K)
Flow − return while heating
5.1 K
House needs at −3 °C
6.1 kW (unit rated 10 kW) · fit r² 0.29
Hot water
no hot-water flag in data
infoNo configuration faults detected in this window
Keep the current settings. We will alert you if efficiency drifts.
noteOwner’s note on the source site: “Unchecked primary circ pump flow rate change without visible pump power change”
valueReaching the fleet’s January median (3.69) would have saved about £13 in this window at 0.25 GBP/kWh. An estimate, not a promise.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day028562026-01-05: 55.5 kWh, outside -1.4 °C2026-01-06: 47.1 kWh, outside 2.3 °C2026-01-07: 38.2 kWh, outside 3.2 °C2026-01-08: 52.3 kWh, outside 0.7 °C2026-01-09: 49 kWh, outside 0.7 °C2026-01-10: 44.7 kWh, outside 2.5 °C2026-01-11: 25.3 kWh, outside 6.9 °C2026-01-12: 20 kWh, outside 8.6 °C2026-01-13: 27.8 kWh, outside 5.1 °C2026-01-14: 29.4 kWh, outside 5.4 °C2026-01-15: 20.7 kWh, outside 4.8 °C2026-01-16: 37.9 kWh, outside 3.8 °C2026-01-17: 26.3 kWh, outside 5.6 °C2026-01-18: 25.7 kWh, outside 5.4 °C2026-01-19: 25.7 kWh, outside 4.8 °C2026-01-20: 21.5 kWh, outside 7.2 °C2026-01-21: 20.8 kWh, outside 6.8 °C2026-01-22: 21.3 kWh, outside 7.3 °C2026-01-23: 24.5 kWh, outside 6.1 °C2026-01-24: 23.3 kWh, outside 6.4 °C2026-01-25: 23.2 kWh, outside 6.3 °C2026-01-26: 28.4 kWh, outside 4.5 °C2026-01-27: 33 kWh, outside 4.4 °C2026-01-28: 23.4 kWh, outside 5.7 °C2026-01-29: 29.9 kWh, outside 4.2 °C2026-01-30: 31.7 kWh, outside 4.1 °C2026-01-31: 24.1 kWh, outside 6.5 °C2026-02-01: 22.5 kWh, outside 6.3 °C2026-02-02: 27.3 kWh, outside 6 °C2026-02-03: 35.3 kWh, outside 4.3 °C2026-02-04: 1.8 kWh, outside 3.4 °Cdaily COP (heat ÷ electricity)1352026-01-05: COP 2.552026-01-06: COP 2.82026-01-07: COP 3.112026-01-08: COP 2.432026-01-09: COP 2.592026-01-10: COP 2.872026-01-11: COP 4.182026-01-12: COP 4.622026-01-13: COP 3.762026-01-14: COP 3.72026-01-15: COP 3.722026-01-16: COP 3.072026-01-17: COP 3.952026-01-18: COP 42026-01-19: COP 3.832026-01-20: COP 4.252026-01-21: COP 4.282026-01-22: COP 4.252026-01-23: COP 42026-01-24: COP 4.122026-01-25: COP 4.112026-01-26: COP 3.722026-01-27: COP 3.462026-01-28: COP 3.92026-01-29: COP 3.462026-01-30: COP 3.482026-01-31: COP 4.122026-02-01: COP 4.232026-02-02: COP 3.882026-02-03: COP 3.322026-02-04: COP 3.0701-0501-0901-1301-1701-2101-2501-2902-02
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
2030405060-6-4-2024681012outdoor temperature, °Cflow temperature, °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.