Stiebel Eltron WPE-I 12 HK Premium

Shetland · Detached · 319 m² · 2012 or newer · 12 kW · underfloor · installed by A J Pottinger

Last 30 days

663 hourly rows · MID-class heat meter present: yes
4.27efficiency (COP) over 663 hours, from the heat meter
better than 90% of the metered fleet in January 2026
Electricity used
481 kWh
Heat delivered
2055 kWh (heat meter)
Estimate without heat meter
flow sensor 2.58 · temperature model 4.22
Mean outdoor temperature
9.7 °C · 362 space-heating hours · cooling 0 kWh removed (0 kWh electricity), kept out of the COP
Flow temperature at 0 °C outside
42.3 °C (curve slope -0.40 per K)
Flow − return while heating
5.6 K
House needs at −3 °C
5.0 kW (unit rated 12 kW) · fit r² 0.04
Hot water
57% of electricity, COP 3.31
warningHot water uses 57% of electricity at COP 3.31
Lower the tank target to 45–48 °C, heat water once a day in the warmest hours, and disable weekly legionella cycles unless required.
infoUnit is rated 12 kW but the house needs about 5 kW at −3 °C
Oversizing causes cycling in mild weather. Cannot be fixed cheaply now, but the curve and minimum run time can limit the damage.
noteOwner’s note on the source site: “0W standby power review required”

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day011232026-10-08: 10.9 kWh, outside 8.6 °C2026-10-09: 15.6 kWh, outside 9.9 °C2026-10-10: 18 kWh, outside 8.6 °C2026-10-11: 15.4 kWh, outside 8 °C2026-10-12: 14.4 kWh, outside 10.2 °C2026-10-13: 11.3 kWh, outside 11.9 °C2026-10-14: 14.9 kWh, outside 11.5 °C2026-10-15: 15.5 kWh, outside 10.7 °C2026-10-16: 17.3 kWh, outside 8.2 °C2026-10-17: 14.5 kWh, outside 8.9 °C2026-10-18: 15.4 kWh, outside 9.4 °C2026-10-19: 13.7 kWh, outside 10.6 °C2026-10-20: 17.1 kWh, outside 11.1 °C2026-10-21: 14.6 kWh, outside 10.8 °C2026-10-22: 18.1 kWh, outside 9.9 °C2026-10-23: 15.1 kWh, outside 8.6 °C2026-10-24: 20.2 kWh, outside 8.3 °C2026-10-25: 18.5 kWh, outside 9.5 °C2026-10-26: 13.3 kWh, outside 9.5 °C2026-10-27: 16.2 kWh, outside 10.7 °C2026-10-28: 17.2 kWh, outside 9.8 °C2026-10-29: 15.2 kWh, outside 11.7 °C2026-10-30: 12.3 kWh, outside 11.5 °C2026-10-31: 14 kWh, outside 10.4 °C2026-11-01: 17.9 kWh, outside 8.4 °C2026-11-02: 18.8 kWh, outside 9.7 °C2026-11-03: 11.6 kWh, outside 9.5 °C2026-11-04: 22.6 kWh, outside 8.8 °C2026-11-05: 19.8 kWh, outside 8.4 °C2026-11-06: 17.4 kWh, outside 8.5 °C2026-11-07: 4.7 kWh, outside 7.9 °Cdaily COP (heat ÷ electricity)1352026-10-08: COP 4.282026-10-09: COP 4.112026-10-10: COP 3.952026-10-11: COP 4.412026-10-12: COP 4.262026-10-13: COP 4.92026-10-14: COP 4.242026-10-15: COP 4.392026-10-16: COP 4.32026-10-17: COP 4.052026-10-18: COP 4.182026-10-19: COP 4.32026-10-20: COP 4.322026-10-21: COP 4.182026-10-22: COP 4.382026-10-23: COP 4.312026-10-24: COP 4.212026-10-25: COP 4.22026-10-26: COP 4.692026-10-27: COP 4.292026-10-28: COP 4.072026-10-29: COP 4.292026-10-30: COP 4.32026-10-31: COP 4.672026-11-01: COP 4.362026-11-02: COP 4.152026-11-03: COP 4.352026-11-04: COP 4.192026-11-05: COP 4.052026-11-06: COP 4.152026-11-07: COP 4.3310-0810-1210-1610-2010-2410-2811-0111-05
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
20304050603579111315outdoor temperature, °Cflow temperature, °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.