Heatproof
Home / system #267

Stiebel Eltron WPE-I 12 HK Premium

Shetland · Detached · 319 m² · 2012 or newer · 12 kW · underfloor · installed by A J Pottinger

5 Jan – 4 Feb 2026 (winter reference)

721 hourly rows · MID-class heat meter present: yes
3.67efficiency (COP) over 721 hours, from the heat meter
better than 50% of the metered fleet in January 2026
Electricity used
917 kWh
Heat delivered
3367 kWh (heat meter)
Estimate without heat meter
flow sensor 2.44 · temperature model 3.19
Mean outdoor temperature
4.4 °C · 464 space-heating hours
Flow temperature at 0 °C outside
44.2 °C (curve slope -0.59 per K)
Flow − return while heating
5.8 K
House needs at −3 °C
6.2 kW (unit rated 12 kW) · fit r² 0.14
Hot water
50% of electricity, COP 3.20
warningHot water uses 50% of electricity at COP 3.2
Lower the tank target to 45–48 °C, heat water once a day in the warmest hours, and disable weekly legionella cycles unless required.
noteOwner’s note on the source site: “0W standby power review required”
valueReaching the fleet’s January median (3.69) would have saved about £1 in this window at 0.25 GBP/kWh. An estimate, not a promise.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day019382026-01-05: 37.9 kWh, outside 0.1 °C2026-01-06: 36.9 kWh, outside 1.1 °C2026-01-07: 35.6 kWh, outside 2.5 °C2026-01-08: 32.5 kWh, outside 2.2 °C2026-01-09: 28.9 kWh, outside 4.3 °C2026-01-10: 30.9 kWh, outside 4.4 °C2026-01-11: 30.1 kWh, outside 5.6 °C2026-01-12: 22 kWh, outside 8.2 °C2026-01-13: 26 kWh, outside 5.7 °C2026-01-14: 27.4 kWh, outside 5.3 °C2026-01-15: 26.3 kWh, outside 6.3 °C2026-01-16: 25.8 kWh, outside 4.3 °C2026-01-17: 26.5 kWh, outside 7.2 °C2026-01-18: 26.6 kWh, outside 7.7 °C2026-01-19: 24 kWh, outside 7.5 °C2026-01-20: 23.1 kWh, outside 7.7 °C2026-01-21: 25.5 kWh, outside 6.1 °C2026-01-22: 28.6 kWh, outside 5.2 °C2026-01-23: 32.4 kWh, outside 3.5 °C2026-01-24: 31.6 kWh, outside 3.6 °C2026-01-25: 30.6 kWh, outside 3.7 °C2026-01-26: 35.9 kWh, outside 3.6 °C2026-01-27: 34.2 kWh, outside 3.1 °C2026-01-28: 33.6 kWh, outside 4 °C2026-01-29: 33.3 kWh, outside 3.4 °C2026-01-30: 31.2 kWh, outside 2.8 °C2026-01-31: 34.3 kWh, outside 4.1 °C2026-02-01: 33.3 kWh, outside 4.1 °C2026-02-02: 34.7 kWh, outside 2.7 °C2026-02-03: 36 kWh, outside 1.2 °C2026-02-04: 1.3 kWh, outside 2.1 °Cdaily COP (heat ÷ electricity)1352026-01-05: COP 3.582026-01-06: COP 3.62026-01-07: COP 3.592026-01-08: COP 3.632026-01-09: COP 3.72026-01-10: COP 3.732026-01-11: COP 3.722026-01-12: COP 3.712026-01-13: COP 3.792026-01-14: COP 3.842026-01-15: COP 3.82026-01-16: COP 3.832026-01-17: COP 3.722026-01-18: COP 3.772026-01-19: COP 3.892026-01-20: COP 3.82026-01-21: COP 3.732026-01-22: COP 3.82026-01-23: COP 3.682026-01-24: COP 3.712026-01-25: COP 3.72026-01-26: COP 3.652026-01-27: COP 3.542026-01-28: COP 3.62026-01-29: COP 3.552026-01-30: COP 3.62026-01-31: COP 3.572026-02-01: COP 3.562026-02-02: COP 3.592026-02-03: COP 3.522026-02-04: COP 3.9701-0501-0901-1301-1701-2101-2501-2902-02
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
2030405060-6-4-20246810outdoor temperature, °Cflow temperature, °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.