Stiebel Eltron WPE-I 12 HK Premium

Shetland · Detached · 319 m² · 2012 or newer · 12 kW · underfloor · installed by A J Pottinger

Last 7 days

144 hourly rows · MID-class heat meter present: yes
4.25efficiency (COP) over 144 hours, from the heat meter
better than 90% of the metered fleet in January 2026
Electricity used
124 kWh
Heat delivered
525 kWh (heat meter)
Estimate without heat meter
flow sensor 2.92 · temperature model 4.13
Mean outdoor temperature
8.9 °C · 80 space-heating hours
Flow temperature at 0 °C outside
42.6 °C (curve slope -0.47 per K)
Flow − return while heating
6.0 K
House needs at −3 °C
2.9 kW (unit rated 12 kW) · fit r² 0.00
Hot water
55% of electricity, COP 3.37
warningHot water uses 55% of electricity at COP 3.37
Lower the tank target to 45–48 °C, heat water once a day in the warmest hours, and disable weekly legionella cycles unless required.
infoUnit is rated 12 kW but the house needs about 2.9 kW at −3 °C
Oversizing causes cycling in mild weather. Cannot be fixed cheaply now, but the curve and minimum run time can limit the damage.
noteOwner’s note on the source site: “0W standby power review required”

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day011232026-10-31: 9.8 kWh, outside 9.8 °C2026-11-01: 17.9 kWh, outside 8.4 °C2026-11-02: 18.8 kWh, outside 9.7 °C2026-11-03: 11.6 kWh, outside 9.5 °C2026-11-04: 22.6 kWh, outside 8.8 °C2026-11-05: 19.8 kWh, outside 8.4 °C2026-11-06: 17.4 kWh, outside 8.5 °C2026-11-07: 5.8 kWh, outside 7.6 °Cdaily COP (heat ÷ electricity)1352026-10-31: COP 4.632026-11-01: COP 4.362026-11-02: COP 4.152026-11-03: COP 4.352026-11-04: COP 4.192026-11-05: COP 4.052026-11-06: COP 4.152026-11-07: COP 4.5610-3111-0111-0211-0311-0411-0511-0611-07
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
203040506045678910111213outdoor temperature, °Cflow temperature, °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.