Heatproof
Home / system #625

Viessmann Vitocal 150A

Marston Moretaine · Detached · 134.61 m² · 2012 or newer · 8 kW · radiators · installed by JMR Heating and Energy

1–31 Dec 2025

745 hourly rows · MID-class heat meter present: yes
3.58efficiency (COP) over 745 hours, from the heat meter
better than 42% of the metered fleet in January 2026
Electricity used
712 kWh
Heat delivered
2552 kWh (heat meter)
Estimate without heat meter
flow sensor 3.72 · temperature model 3.55
Mean outdoor temperature
7.0 °C · 604 space-heating hours
Flow temperature at 0 °C outside
38.2 °C (curve slope -0.56 per K)
Flow − return while heating
1.8 K
House needs at −3 °C
4.4 kW (unit rated 8 kW) · fit r² 0.40
Hot water
34% of electricity, COP 3.10
warningOnly 1.8 K between flow and return
Circulation pump may be set too high or emitters are undersized for the low flow temperature. Ask the installer to check pump speed.
warningHot water uses 34% of electricity at COP 3.1
Lower the tank target to 45–48 °C, heat water once a day in the warmest hours, and disable weekly legionella cycles unless required.
valueReaching the fleet’s January median (3.69) would have saved about £5 in this window at 0.25 GBP/kWh. An estimate, not a promise.

Day by day

electricity per daydaily COP3.0 floor
electricity, kWh per day020392025-12-01: 18.7 kWh, outside 9.9 °C2025-12-02: 16.9 kWh, outside 8.1 °C2025-12-03: 22.1 kWh, outside 5.2 °C2025-12-04: 25.9 kWh, outside 6.1 °C2025-12-05: 27 kWh, outside 4.7 °C2025-12-06: 14.8 kWh, outside 9.8 °C2025-12-07: 17.2 kWh, outside 10.1 °C2025-12-08: 14.7 kWh, outside 11.4 °C2025-12-09: 12.5 kWh, outside 12.5 °C2025-12-10: 16.3 kWh, outside 10 °C2025-12-11: 21.3 kWh, outside 8.9 °C2025-12-12: 16.8 kWh, outside 9 °C2025-12-13: 22.6 kWh, outside 5.6 °C2025-12-14: 22.4 kWh, outside 8.6 °C2025-12-15: 16.2 kWh, outside 10.3 °C2025-12-16: 20.1 kWh, outside 7.6 °C2025-12-17: 25 kWh, outside 5.4 °C2025-12-18: 19.5 kWh, outside 10.5 °C2025-12-19: 20.3 kWh, outside 7.4 °C2025-12-20: 23.5 kWh, outside 5 °C2025-12-21: 18.4 kWh, outside 8.5 °C2025-12-22: 18.6 kWh, outside 8.4 °C2025-12-23: 25.1 kWh, outside 5.9 °C2025-12-24: 31.5 kWh, outside 4 °C2025-12-25: 36.2 kWh, outside 2.8 °C2025-12-26: 33.8 kWh, outside 3.1 °C2025-12-27: 30.6 kWh, outside 3.9 °C2025-12-28: 24.9 kWh, outside 5.4 °C2025-12-29: 28.3 kWh, outside 5.1 °C2025-12-30: 30.7 kWh, outside 3.6 °C2025-12-31: 39.2 kWh, outside 0.8 °C2026-01-01: 1.1 kWh, outside 0.9 °Cdaily COP (heat ÷ electricity)1352025-12-01: COP 4.12025-12-02: COP 4.132025-12-03: COP 3.582025-12-04: COP 3.52025-12-05: COP 3.352025-12-06: COP 4.142025-12-07: COP 4.012025-12-08: COP 4.032025-12-09: COP 4.232025-12-10: COP 4.022025-12-11: COP 3.772025-12-12: COP 4.012025-12-13: COP 3.712025-12-14: COP 3.842025-12-15: COP 4.082025-12-16: COP 3.772025-12-17: COP 3.52025-12-18: COP 3.992025-12-19: COP 3.812025-12-20: COP 3.542025-12-21: COP 3.862025-12-22: COP 3.912025-12-23: COP 3.582025-12-24: COP 3.232025-12-25: COP 3.122025-12-26: COP 3.052025-12-27: COP 3.222025-12-28: COP 3.642025-12-29: COP 3.392025-12-30: COP 3.272025-12-31: COP 2.832026-01-01: COP 3.4712-0112-0512-0912-1312-1712-2112-2512-29
Daily COP needs a heat meter; days without one show electricity only.

The installed heating curve

one heating hourfitted curve50 °C
2030405060-3-113579111315outdoor temperature, °Cflow temperature, °C
Each point is one hour of space heating. Lower and flatter is cheaper; well-set radiator systems sit around 35–42 °C at 0 °C outside.
Public system published by its owner on HeatpumpMonitor.org. Cycling (starts per hour) comes from the site’s 365-day statistic. Findings use installer rules of thumb; see methodology.